VAW Meters for Power and Performance Testing

Voltage, Current and Wattage Measurement for Appliances, Motors and Industrial Loads

Models: PE 150 · PE 155 · PE 155-3

Need Pricing or Technical Assistance on VAW Meters?

Speak directly with our team for product selection, pricing, technical support and customised testing solutions.

Power Measurement for Test Floors and Laboratories

Clear, real-time voltage, current and wattage readings for performance testing and calibration. Choose a single-phase meter with built-in dimmer (PE 150), a panel meter (PE 155), or a three-phase meter (PE 155-3). Optional RS 485 sends data to a PC or cloud system.

Enquiring? Share the load rating, phase, parameters needed and whether you need a variable voltage supply, and we will configure the meter around them.

Certifications

  • ISO Certified
  • NABL Accredited

Choose Your VAW Meter

ModelPhaseVoltageCurrentDisplay
PE 150Single0-500 V AC (dimmer)10 mA to 60 A4-digit V, A, W
PE 155Single0-500 V AC5 A direct, CT above4-digit V, A, W
PE 155-3Three500 V direct, PT above5 A direct, CT above3 rows of 4-digit

VAW Meter with Dimmer: PE 150

Premier PE 150 VAW Meter with Dimmer

Key Features

Direct display of V, A, W, PF, frequency, energy, VA and kVAh
Dimmer-controlled 0-500 V AC output, up to 60 Amp
6/16 Amp sockets with MCB input protection
NABL-traceable calibration certificate

Technical Specifications

Power Input230 V AC ± 10%, 50 Hz
DisplayIndividual 4-digit voltage, current and wattage
Voltage OutputUser-settable 0-270 V AC ± 10%, or 0-500 V AC
Load Current10 mA to 60 A
Load Wattage0-5.00 kW
SafetyMCB protection
Dimensions30 cm (W) × 18 cm (H) × 25 cm (D)
OptionsRS 485, 3-phase output, additional parameters, 1-60 A load models

VAW Meter: PE 155

Premier PE 155 VAW Meter

Key Features

Direct display of voltage, current and wattage
Appliance, motor, accessory and heater testing
NABL-traceable calibration certificate

Technical Specifications

DisplayIndividual 4-digit V, A, W
Voltage0-500 V AC
Current5 A direct; CT above 5 A
CT SelectionPrimary and secondary programmable
Load Wattage0.001 W-9999 kW, autoranging
Power Supply90-270 V AC/DC
Optional DisplayEnergy, frequency, PF, load hours, run hours, THD, active and apparent power
Dimensions96 mm (W) × 96 mm (H)

3-Phase VAW Meter: PE 155-3

Premier PE 155-3 three-phase VAW Meter

Key Features

Line-to-line and line-to-neutral voltage, current, frequency, PF, kW, kVA, kWh, RPM, run and load hours
For three-phase appliances, motors, accessories and heaters
NABL-traceable calibration certificate

Technical Specifications

Power Input230 V AC ± 10%, 50 Hz
Display3 rows of 4-digit display
Current Input5 A direct; CT above, programmable
Voltage Input500 V direct; PT above, programmable
ParametersL-L & L-N voltage, current, frequency, PF, watt, kVA, kVAr, kWh, kVArh, kVAh, RPM, run hours, load hours
Dimensions96 mm (W) × 96 mm (H) × 57 mm (D)
OptionsDimmer 0-500 V; 13-level THD, K factor, LCD screen

Applications

Appliance manufacturing Motor testing Electrical accessories Heater testing Quality control Service centres R&D laboratories Industrial loads

How to Choose a VAW Meter

Use these six steps to select the right model.

1. Single or three phase?

PE 150 and PE 155 for single phase. PE 155-3 for three-phase appliances, motors and heaters.

2. Need a variable supply?

PE 150 has a built-in dimmer, 0-500 V AC up to 60 Amp. PE 155-3 offers an optional 0-500 V dimmer.

3. Check the load

PE 150 covers 10 mA to 60 A (up to 5.00 kW). PE 155 and PE 155-3 take 5 A directly and use a CT above that.

4. List the parameters

V, A, W as standard. Options add PF, frequency, energy, VA, kVAh, THD, run hours and load hours.

5. Decide on connectivity

Optional RS 485 for data transfer to a PC or cloud-connected system.

6. Ask for your configuration

Share load rating and parameters. We configure the meter to suit, with NABL-traceable calibration.

Product Video

Frequently Asked Questions

VAW Meters can measure voltage, current, wattage and, depending on the model and options, power factor, frequency, energy, VA, kVAh, harmonics and run hours.

Premier offers the PE 150 VAW Meter with Dimmer, the PE 155 VAW Meter and the PE 155-3 three-phase VAW Meter.

Yes. These meters are suitable for manufacturers, service centres, R&D facilities and performance testing of appliances, motors, accessories and industrial loads.

The PE 150 has a dimmer-controlled output of 0-500 V AC, up to 60 Amp. A dimmer for 0-500 V is also optional on the PE 155-3.

The PE 155 takes up to 5 A directly; above 5 A use a CT with programmable primary and secondary. The PE 155-3 takes up to 5 A and 500 V directly; above that use a user-programmable CT or PT.

Yes. Premier VAW Meters are supplied with an NABL-traceable calibration certificate.

Ready to Discuss Your Testing Requirement?

Our technical experts are ready to help you select the right VAW meter and provide the best quotation for your application.

40+ Years
Industry Experience
50+ Countries
Worldwide Customers
Made in India
Trusted Testing Solutions