Applications:

Premier Electrosystems' Standing Loss System is used to calculate the energy consumption measurement of a filled water heater, after steady state conditions have been reached when connected to electrical supply and when no water is drawn for a minimum of 48 hours.

The star rating for the electric geysers is given based on the standing losses. Standing loss or heat/energy loss of a water heater to the surrounding in 48 hours is an important factor used by BEE (Bureau of Energy Efficiency) to decide on star rating of a water heater.

The unit of Standing Loss is Energy consumed per 24 hrs for a difference of 45 ° C (kWh/24 hrs/ 45 ° C).

STANDING LOSS TEST SYSTEM STAR RATING CALCULATOR FOR GEYSER

Premier Electrosystems' Standing Loss Test System

Designed to suit the requirement of IS: 2082, and other similar standards.

SPECIFICATIONS:


  1. Voltage:
    Range: 0-300.0 V
    Least Count: 0.1 V

  2. Current:
    Range: 0-20.00 Amp
    Least count: 0.01 A

  3. Wattage:
    Range: 0-10.000 W
    Least count: 0.001 W

  4. Energy (KW-h):
    Range: 0-99.000 Kwh
    Least count: 0.001 KWh

  5. Temperature:
    Type: RTD- rod type with nut mounting to directly fit into geyser outlet pipe.
    Range: 0-100.0 ° C
    Least count: 0.1 ° C

  6. Room temperature sensor:
    Type: TC- K type
    Range: 10-60 ° C
    Least count: 1 ° C

LOGGING SECTION:

  1. Logging of above 6 parameters directly into pen drive
  2. Log rate settable from 15 sec onwards up to 99 sec
  3. Inbuilt Real-time clock

PC SOFTWARE:

  1. Direct report generation
  2. Easy access to raw data
  3. Easy option to create graphs of data

Inclusions:

  1. Modular fitting box for panel mounting arrangement
  2. All sensors, CT's calibrated as per NABL
  3. Pen drive- 8 GB

Screenshot of the software